Metal-Clad Switchgear

New American-built power distribution equipment, engineered around your project.

ENGINEERED FOR POWER
US
Made in the USAAmerican components
✓
Project-specific standardsConfirmed for equipment type
↗
Built to moveLead time quoted by project

PRODUCTS / MANUFACTURER DIRECT

Metal-clad switchgear is a medium-voltage lineup arranged with grounded metal barriers that separate major compartments. For buyers, the important questions go beyond the label: which equipment class and applicable IEEE standard edition does the project require, what breaker arrangement fits the system, and how will the lineup be accessed and maintained? Switchgear Builder Virginia manufactures new, custom-built switchgear in the USA using all-American components, with nationwide shipping. Configuration, ratings, applicable standards, schedules, and availability must be confirmed against the project documents and quote.

Metal barriers and compartments

Metal barriers divide the lineup into functional spaces, such as breaker, bus, and cable compartments. Their purpose is to limit exposure between areas and support the equipment’s specified construction—not to make every internal task safe or eliminate the need for approved procedures. Buyers should compare the required compartment arrangement with one-line diagrams, cable entry locations, bus connections, and the utility or facility’s operating practices. Ask which components are separated, how access doors and shutters are arranged, and what barriers are included in the quoted configuration. Do not assume that two lineups described as metal-clad have identical layouts or features. The project specification should identify the applicable IEEE standard edition and exact equipment class; confirm both before comparing proposals, since the name alone does not establish the required design, testing, or rating.

Breaker arrangement

Drawout breakers can be moved between operating and disconnected positions using the equipment’s intended mechanism, allowing certain inspection or maintenance tasks to be planned without removing the breaker from its compartment. The actual positions, interlocks, racking method, and permitted work depend on the selected design and project requirements. Buyers should verify breaker type, continuous-current and interrupting requirements, control voltage, trip functions, and compatibility with the specified lineup. Confirm whether spare breakers or future breaker positions are required, and whether those provisions are included in the proposed scope. A drawout arrangement can aid access, but it adds design and operating considerations that a fixed arrangement may not share. Compare the practical maintenance plan, space needs, and operating procedures—not just the presence of a drawout breaker—before settling the configuration.

Ratings and IEEE class

Medium-voltage switchgear must be selected against the system’s documented electrical requirements. The buyer’s engineer and project documents should establish nominal voltage, insulation level, continuous current, short-circuit duties, protective-device coordination, and any environmental or installation conditions that apply. Do not infer a rating from a catalog phrase, a voltage number, or another project’s equipment. The exact IEEE standard edition and equipment class are important because they define the basis for evaluating the requested equipment; provide the specification, one-line diagram, and relevant schedules for review. Switchgear Builder Virginia can configure new, custom-built equipment against confirmed project requirements, but ratings and scope remain subject to quote and verification. Clarify any exceptions in writing, including assumptions about incoming feeds, bus arrangement, metering, relaying, and control interfaces, before approving a proposal.

Maintenance access planning

Access needs should be settled during layout review, not left until installation. Check the room plan for front, rear, and end access as required by the selected design, plus working space, door swing, cable termination room, and a route for moving breakers or other serviceable components. Confirm which side contains cable entry and whether the lineup must align with existing conduits, trenches, or bus connections. A compact footprint may simplify room planning but can constrain access or future changes; a larger arrangement can provide more working room while requiring additional floor space. These are project tradeoffs, not universal features. Review the proposed outline and connection details with the electrical design team and installation contractor, and verify that access provisions match site conditions and applicable project requirements. Never rely on a generic layout as a substitute for the approved drawings.

Scope and submittal review

A useful proposal review compares the same defined scope across suppliers. Identify the lineup sections, breaker quantities and types, bus arrangement, instrument transformers, protective relays, metering, control wiring, and required accessories. Mark each item as specified, included, excluded, or awaiting clarification. Confirm the requested IEEE edition and equipment class, then check that the submitted drawings and ratings align with the project documents. If existing systems constrain connections or room dimensions, share verified drawings and field information; do not assume compatibility without engineering review. Switchgear Builder Virginia manufactures new equipment in the USA with all-American components and offers custom builds and nationwide shipping. Lead times and schedules are subject to quote and verification, so request project-specific confirmation rather than relying on a general estimate. Final configuration and ratings must be confirmed before release.

Related project guides

START A CONVERSATION

Let’s build the right solution.

Tell us what you’re building, replacing or upgrading. Share the information you have now; project details and availability can be confirmed together.

PREFER TO TALK?

(951) 403-5738

Virginia projects. Nationwide delivery.

This attempts to open a draft in your configured email app; review and send it there. Browser support varies. For immediate assistance, call (951) 403-5738.

Request a quote