Molded-Case Circuit Breaker Switchboards

New American-built power distribution equipment, engineered around your project.

ENGINEERED FOR POWER
US
Made in the USAAmerican components
✓
UL 891 assembliesFor applicable switchboards
↗
Built to moveLead time quoted by project

PRODUCTS / MANUFACTURER DIRECT

Molded-case circuit breaker switchboards bring multiple feeder and main-device choices into one low-voltage assembly. The useful design question is not simply which breaker fits: frame size, trip function, available fault current, load mix, and coordination must work together within the project’s electrical and physical requirements. Switchgear Builder Virginia manufactures custom new switchboards in the USA with all-American components and ships nationwide. The details below help organize a specification and identify items to confirm during quotation. Device selections, ratings, construction, schedule, and any applicable assembly requirements depend on the project documents and verification.

Frame size and rating

A molded-case breaker’s frame identifies a device family and its maximum current capability; it does not, by itself, establish the trip setting or the protection the connected circuit needs. Specify each feeder’s design current, conductor and load information, and required protection, then confirm the breaker’s frame, sensor or rating plug where applicable, and trip-unit range against those needs. Avoid treating a larger frame as a simple upgrade: it can affect space, connections, settings, and coordination, while an unsuitable trip choice can leave equipment inadequately protected. The main breaker and feeder breakers also need to fit the selected switchboard construction and bus arrangement. Switchgear Builder Virginia can develop a custom new assembly from documented requirements; final device availability, dimensions, ratings, and compatibility are subject to quote and engineering verification.

Trip functions

Trip functions determine how a breaker responds to different electrical conditions. Depending on device type and project requirements, trip protection may include long-time, short-time, instantaneous, and ground-fault functions; not every breaker offers every function, and settings are not interchangeable. A useful schedule identifies the protection needed at each position and distinguishes device capability from the settings to be applied. Where electronic trip units are considered, document required functions, adjustment ranges, accessories, and any interface or indication needs rather than relying on a model name alone. Confirm that chosen functions suit the load, conductors, upstream and downstream devices, and applicable design documents. The final selection should be reviewed by qualified project professionals. A quotation can reflect specified trip requirements, but actual device features, setting ranges, and assembly details must be checked for the selected equipment.

Feeder mix and layout

Build a feeder schedule that shows each circuit’s purpose, quantity, current requirement, poles, and breaker preferences, along with the main-device arrangement and any planned spare spaces. Mixed feeder sizes can influence the lineup’s width, usable section space, bus distribution, cable entry, wire-bending room, and termination access. A schedule that lists only amperage may miss practical constraints such as conductor count, lug requirements, top or bottom entry, and future circuit provisions. Identify loads that may require special protection or switching, and flag items still awaiting engineering rather than silently assigning a standard breaker. These details help align the electrical design with the physical installation and reduce late changes. Switchgear Builder Virginia offers custom new switchboard builds; the proposed feeder mix and dimensions remain subject to review of drawings, equipment selection, and quoted configuration.

Coordination and fault duty

Coordination is a system-level review of how protective devices respond to faults, with the goal of determining whether the intended device clears a fault while upstream devices remain appropriately coordinated. It cannot be established by selecting breakers independently or by assuming that similar trip settings produce selective operation. Provide available fault-current information, upstream and downstream device data, transformer details when relevant, and the project’s coordination study or required criteria. Separately confirm each breaker’s interrupting rating at the applicable voltage and the assembly’s short-circuit rating against the verified system conditions. These are related but distinct checks; a satisfactory interrupting rating alone does not demonstrate coordination. Qualified engineers should evaluate settings and study results. Switchgear Builder Virginia can consider documented requirements in a custom quote, but interrupting, short-circuit, and coordination details require project-specific confirmation.

Assembly requirements

Before ordering, reconcile the one-line diagram, breaker schedule, specifications, available fault-current data, enclosure and mounting needs, cable-entry plan, and site constraints. Identify required accessories, metering or indication, neutral and ground arrangements, and any future capacity, then verify each item against the selected assembly rather than assuming it is included. For applicable low-voltage switchboards, UL 891 assembly requirements should be specified and confirmed for the quoted configuration; that reference does not establish a breaker’s interrupting rating or prove a project-specific approval. Review submittals and ratings before release, and resolve discrepancies through the responsible design and procurement teams. Switchgear Builder Virginia manufactures new switchgear in the USA using all-American components and ships nationwide. Lead times, ratings, options, and applicable assembly details are confirmed by quotation and verification, not inferred from a general product description.

Related project guides

START A CONVERSATION

Let’s build the right solution.

Tell us what you’re building, replacing or upgrading. Share the information you have now; project details and availability can be confirmed together.

PREFER TO TALK?

(951) 403-5738

Virginia projects. Nationwide delivery.

This attempts to open a draft in your configured email app; review and send it there. Browser support varies. For immediate assistance, call (951) 403-5738.

Request a quote