Custom switchboards bring the service entrance, distribution, metering, and enclosure into a coordinated assembly—but the right arrangement depends on the building’s load, utility requirements, available space, and operating priorities. Switchgear Builder Virginia manufactures new, custom switchboards in the USA using all-American components, with nationwide shipping and short lead times subject to project scope and quote. This guide outlines decisions to define before requesting a configuration. Final dimensions, ratings, standards, schedule, and options must be confirmed against project documents and applicable requirements.

Main and feeder sections

Start with the one-line diagram and identify where the service conductors terminate, how the main disconnect is arranged, and which loads need individual feeders. A main section may house service conductors and a main protective device; feeder sections distribute power through breakers or other specified devices. The physical lineup can place the main first, group sections by load, or reserve space for future circuits, but each choice affects footprint, cable routing, access, and coordination with connected equipment. List feeder quantities, device types, frame or trip requirements, and conductor entry direction early. Avoid treating spare spaces as usable capacity until bus, enclosure, and protective-device provisions are confirmed. A clear load schedule and one-line diagram help resolve ambiguities before layout begins. Final configuration depends on verified electrical data and applicable project requirements.

Metering choices

Metering should answer a defined operational question: utility billing, tenant allocation, energy monitoring, or local indication. The purpose influences instrument type, measurement points, communications needs, and whether readings must be visible at the switchboard or gathered by another system. Confirm whether the utility specifies a particular metering arrangement, compartment, test provisions, or access requirements; do not assume a preferred utility configuration will fit every service. Also identify who supplies meters, current transformers, voltage connections, and communications equipment, and verify compatibility with the specified lineup. More measurement points can improve visibility but add components, wiring, space, and commissioning coordination. Simpler metering can reduce complexity when only service-level readings are needed. State the intended use, required quantities, and interface expectations in the inquiry so the proposed arrangement can be checked against project documents and utility direction.

Bus rating and protection

Bus selection is not a guess based on the largest breaker alone. The design team should establish the required ampere rating from the service and load data, then verify the assembly configuration against the project’s fault-current information and protective-device requirements. Specify the system voltage, phase and wire arrangement, main and feeder device details, and any requested neutral or ground provisions. These inputs affect bus layout, device selection, and available configurations. A higher rating may provide headroom but can change cost, space, and component choices; selecting a lower rating without a complete load review can constrain future use. Short-circuit and withstand ratings, interrupting ratings, and coordination are distinct checks, not interchangeable labels. Provide the available fault-current data and design criteria for review. Ratings and options are subject to quote and verification; no numerical topic or example establishes a supplied assembly rating.

Enclosure and installation

Choose the enclosure around the actual installation, not a generic assumption about where the board might go. Indoor or outdoor placement, exposure to moisture or dust, room dimensions, working access, cable entry, and mounting conditions can all change the required construction. Identify whether conductors enter from above or below, the available wall or floor space, and any transportation or access limits along the delivery route. A more protective enclosure may suit harsher exposure, while a less demanding environment may favor a simpler arrangement; the required enclosure type must be selected from verified site conditions and project specifications. Confirm dimensions, section lineup, access clearances, and connection details with the project team before release. Do not assume a particular enclosure rating, construction material, finish, or approval is standard. Document each requirement so the proposed design can be reviewed for fit and intended location.

Validate the specification

Before requesting a quote, assemble the one-line diagram, load schedule, service data, available fault-current information, feeder list, metering requirements, site conditions, and target dimensions. Name the applicable standard in the project documents and confirm its scope for the specified assembly; UL 891 applies only to applicable low-voltage switchboards, not medium- or high-voltage switchgear. Any requested listing, inspection, testing, or approval should be identified and verified for the particular configuration rather than presumed. Check that the main and feeder arrangement, bus rating, enclosure, cable entry, and metering all agree across drawings and schedules. Switchgear Builder Virginia can develop custom new equipment with all-American components and ship nationwide; actual configuration, standards, ratings, and schedule remain subject to engineering review and quote. Resolve open items before design release to reduce changes caused by mismatched assumptions.

Related project guides

START A CONVERSATION

Let’s build the right solution.

Tell us what you’re building, replacing or upgrading. Share the information you have now; project details and availability can be confirmed together.

PREFER TO TALK?

(951) 403-5738

Virginia projects. Nationwide delivery.

This attempts to open a draft in your configured email app; review and send it there. Browser support varies. For immediate assistance, call (951) 403-5738.

Request a quote