Medium-Voltage Main-Tie-Main Switchgear

New American-built power distribution equipment, engineered around your project.

ENGINEERED FOR POWER
US
Made in the USAAmerican components
✓
Project-specific standardsConfirmed for equipment type
↗
Built to moveLead time quoted by project

PRODUCTS / MANUFACTURER DIRECT

Medium-voltage main-tie-main switchgear connects two incoming sources to separate bus sections, with a tie breaker available to support a planned transfer. The arrangement can improve continuity, but its value depends on source behavior, protection coordination, operating rules, and the loads that must remain energized. Switchgear Builder Virginia manufactures custom new switchgear in the USA using all-American components and ships nationwide. Define the intended sequence and project boundaries early; voltage class, fault duty, ratings, schedule, and manufacturer scope must be confirmed for the specific project.

Choose the source arrangement

Start by documenting each incoming source, its normal availability, and whether the sources may operate in parallel. A common arrangement has one main breaker feeding each bus section and a tie breaker between sections; the intended normal state may keep the tie open, closed, or subject to a defined operating procedure. These choices affect transfer behavior, protection, and the consequences of losing a source. Identify which loads are essential, whether they can tolerate an interruption, and whether one source can carry the required transferred load. Also clarify whether sources come from separate utility feeds, transformers, generators, or another configuration. Those details are design inputs, not assumptions to settle from a generic diagram. A project-specific one-line diagram gives the manufacturer and electrical engineer a shared basis for reviewing the proposed arrangement, equipment boundaries, and operating intent before ratings and construction details are finalized.

Define tie operation

A bus tie can let one source support both sections when the other source is unavailable, but the transfer method determines what happens during the changeover. Specify whether transfer is manual or automatic, what event initiates it, and whether transfer is open-transition or permits momentary paralleling. Do not assume that a tie breaker should close whenever a main opens: source status, load limits, fault conditions, and utility or generator operating requirements may require the tie to remain open. Describe normal breaker positions and the allowed steps for planned and abnormal conditions. If automatic transfer is required, identify the sensing, timing, permissives, and return-to-normal behavior for engineering review. The sequence must account for the actual sources and system study results. Clear operating descriptions help distinguish the requested functionality from optional controls and keep the switchgear scope aligned with the facility’s operating plan.

Coordinate interlocks

Interlocks help prevent specified breaker operations that could create an unacceptable system condition, such as unintended source paralleling. The project team should state which combinations of main and tie positions are allowed, which are prohibited, and how those restrictions should be implemented. Possible approaches include mechanical, electrical, key-based, or control-logic interlocking, but suitability depends on the design and applicable project requirements. An interlock is not a substitute for a complete operating procedure, protection scheme, or review of source behavior. Confirm how the system should respond to loss of control power, a failed position indication, maintenance conditions, and any bypass or test mode proposed for the design. Review the sequence with the responsible engineer and facility operators so equipment indications and permitted actions are understandable. Switchgear Builder Virginia can develop custom equipment to project requirements; the specific interlock method and functions remain subject to engineering review and quote.

Plan relays and protection

Relay functions should follow the system study and protection philosophy, rather than a generic main-tie-main template. Establish which devices protect each source, bus section, tie, and outgoing feeder, and identify required trip, alarm, and status signals. Coordination must consider available fault current for each permitted operating arrangement, including a bus supported through the tie. Source changes can alter fault levels and protection behavior, so the design team should evaluate normal and transferred configurations. Provide available short-circuit and coordination studies, instrument-transformer requirements, control-power details, and any communications or remote-control interfaces for scope review. Do not treat a relay feature list as proof that a particular scheme is suitable or included. Relay models, settings responsibility, testing, documentation, and integration boundaries should be identified in the quote and project documents. Any required testing or approvals should be confirmed for the specific order.

Verify ratings and scope

Before equipment selection, confirm the system voltage class, insulation requirements, continuous current, short-circuit withstand or interrupting requirements, and applicable site conditions with the project engineer and manufacturer. Fault-duty values must match the available system data and the proposed main, tie, and bus arrangement; a product-page topic or example value does not establish a rating. Clarify whether the quoted scope includes incoming devices, tie breaker, bus, protective relays, controls, metering, compartments, drawings, testing, or specified accessories. Identify connection and interface responsibilities for transformers, cables, grounding, external controls, and field installation. Switchgear Builder Virginia manufactures new custom switchgear in the USA with all-American components and offers nationwide shipping. Voltage class, ratings, included features, lead-time expectations, and testing scope are confirmed through project review and quote; schedules and ratings are not established until verified for the order.

Related project guides

START A CONVERSATION

Let’s build the right solution.

Tell us what you’re building, replacing or upgrading. Share the information you have now; project details and availability can be confirmed together.

PREFER TO TALK?

(951) 403-5738

Virginia projects. Nationwide delivery.

This attempts to open a draft in your configured email app; review and send it there. Browser support varies. For immediate assistance, call (951) 403-5738.

Request a quote