AMERICAN BUILT. PROJECT READY.MANUFACTURER DIRECT (951) 403-5738
Gray switchgear with meters and circuit breakers inside an open enclosure.

BUYING INTENT / VIRGINIA & NATIONWIDE

Switchboard Quote Checklist

New American-built power distribution equipment, engineered around your project.

ENGINEERED FOR POWER
US
Made in the USAAmerican components
✓
UL 891 assembliesFor applicable switchboards
↗
Built to moveLead time quoted by project

BUYING INTENT / MANUFACTURER DIRECT

A useful switchboard quote starts with enough verified information to define the electrical duty, physical layout, and documents required—not with guesses about ratings or delivery. Switchgear Builder Virginia manufactures new, custom switchboards with all-American components and ships nationwide. Use this checklist to organize project inputs before requesting pricing. If a detail is unknown, identify it as pending rather than selecting a value without engineering review. Final configuration, ratings, applicable standards, schedule, and scope must be confirmed for the specific project and reflected in the quote.

Service details

Describe the intended service before comparing switchboard proposals. Share the system voltage, phase, frequency, number of wires, grounding arrangement, and whether the equipment is for a new installation or a planned replacement. Include available utility or project documentation, but flag any information that has not been confirmed. Identify the installation environment, indoor or outdoor location, and any known space, access, or environmental constraints. These details can affect enclosure selection, arrangement, and coordination, so assumptions should be written down. Ask the manufacturer to identify unresolved inputs and state which proposed details depend on later verification. Do not infer a suitable rating from a building description or a nearby piece of equipment. For applicable low-voltage switchboards, confirm whether a UL 891 assembly is required and whether that requirement applies to the requested configuration; it does not apply to medium- or high-voltage switchgear.

Main and feeders

Provide a circuit schedule showing the proposed main device and each feeder, including circuit identification, load or purpose, requested device type, and any known trip or frame requirements. Distinguish confirmed project requirements from preliminary selections. Include future spaces only if they are actually part of the requested scope, and specify whether they should be equipped or left provisioned for later use. Ask the quote to list device quantities, ratings, and arrangement so the proposal can be checked against the schedule. Where available, provide coordination studies, one-line diagrams, or other design documents for review; do not assume a breaker choice from load labels alone. Short-circuit current rating (SCCR) is a key project input, but the required value and proposed assembly rating must be evaluated and verified for the complete configuration. Have the responsible design professional confirm the application and acceptance criteria before ordering.

Metering and controls

List the measurements, indications, and controls the project requires rather than asking for generic metering. Specify which quantities should be displayed or communicated, where they need to be visible, and whether any signals or communications must interface with other equipment. Identify the intended meter locations and any known instrument-transformer or control-power requirements, while marking unconfirmed selections for review. If the project documents call for a particular protocol, device, or monitoring platform, include the exact requirement and ask whether it is included in the proposed scope. Clarify which components, wiring, and accessories are supplied, and which are by others. Metering choices can affect panel space, wiring, and coordination with the electrical design, so resolve them before the layout is finalized where possible. The quote should make exclusions and open questions visible; do not treat an unspecified feature as included or compatible.

Dimensions and layout

Send the available room or equipment-space dimensions, preferred lineup orientation, and any known access limitations. Include door and aisle clearances, wall or floor constraints, cable entry direction, and the intended location of incoming and outgoing conductors when those details are established. Attach a marked-up plan or photographs only when they accurately represent the project, and label measurements that still need field confirmation. Ask the manufacturer to provide proposed overall dimensions and a layout for review before fabrication. A compact arrangement may reduce footprint but can constrain access or future changes; extra space may improve maintainability but may not fit the room. Resolve that tradeoff against the actual site plan and applicable project requirements. Confirm who is responsible for final field measurements, conduit coordination, and installation planning. Do not rely on a preliminary outline as a verified fit or as a substitute for site review.

Documents and quote review

Identify the documents needed with the proposal and for project review, such as a bill of material, equipment schedule, outline drawing, wiring information, and applicable assembly documentation. State any required submittal format, review milestones, and project-specific standards or specifications; the manufacturer should verify which requirements apply to the requested equipment. Compare quotes by checking that service details, main and feeder schedules, metering, dimensions, SCCR, exclusions, and open assumptions align—not merely by comparing totals. Ask the supplier to identify deviations and information needed to finalize the design. Switchgear Builder Virginia builds custom new equipment in the USA using all-American components and ships nationwide. Pricing, ratings, applicable listings or approvals, and schedule remain subject to project review and quote verification. Confirm the agreed scope and documents before authorization, and route technical or code questions to the responsible design professional or authority having jurisdiction.

Related project guides

START A CONVERSATION

Let’s build the right solution.

Tell us what you’re building, replacing or upgrading. Share the information you have now; project details and availability can be confirmed together.

PREFER TO TALK?

(951) 403-5738

Virginia projects. Nationwide delivery.

This attempts to open a draft in your configured email app; review and send it there. Browser support varies. For immediate assistance, call (951) 403-5738.

Request a quote