Switchgear Ratings and Specifications

New American-built power distribution equipment, engineered around your project.

ENGINEERED FOR POWER
US
Made in the USAAmerican components
✓
Project-specific standardsConfirmed for equipment type
↗
Built to moveLead time quoted by project

RATINGS / MANUFACTURER DIRECT

Switchgear ratings describe how equipment is intended to operate and withstand electrical and site conditions; they are not interchangeable catalog numbers. Switchgear Builder Virginia manufactures new equipment in the USA with all-American components and custom build options. Use the specifications below to organize project requirements, then have the proposed design and ratings reviewed against the actual system, drawings, and applicable requirements. Configuration, ratings, schedule, and availability are subject to quote and verification.

System Voltage

Start with the system’s nominal voltage, phase, frequency, grounding arrangement, and point of connection. Then confirm the equipment’s voltage rating and the ratings of connected devices against the actual system conditions; a familiar nominal value alone does not establish suitability. For medium-voltage applications, identify the system voltage and the equipment class required by the design, along with any specified insulation or withstand criteria. For low-voltage applications, clarify whether the project calls for switchgear or a switchboard, since product type and applicable requirements affect the specification. Avoid using a single label such as “480 volt” as a complete design brief. Drawings, utility information, transformer data, and project standards help resolve the details. Switchgear Builder Virginia can review these inputs for a custom new build; final equipment ratings and configuration require project-specific verification.

Continuous Current

Current ratings address normal operating load, but choosing a rating requires more than adding nameplate amperes. Identify present and planned loads, feeder duties, demand assumptions, future expansion, and how loads may operate together. Consider bus current and the ratings of breakers, switches, and other components as separate items to verify; the lowest applicable rating can constrain the assembly’s use. A larger rating may provide useful capacity, but can affect footprint, cost, component selection, and coordination with the rest of the system. Do not treat anticipated growth as a reason to select an arbitrary size: document what is expected and have the design team determine suitable margin. Provide one-line diagrams, load schedules, and known operating scenarios when requesting a quote. Proposed continuous-current ratings, component combinations, dimensions, and pricing remain subject to engineering review and quotation.

Fault Duty

Fault-current requirements need deliberate review because the equipment must be suitable for the available system fault duty and the protective devices selected for it. Share the available fault-current information at the equipment location, the source and transformer details used to determine it, and any specified protective-device arrangement. Distinguish the assembly’s short-circuit rating from an individual breaker’s interrupting rating; related values describe different parts of the design and must be checked together. Protective-device combinations can also affect the rating applicable to an assembly, so do not infer suitability from a breaker label or a headline number alone. The engineer of record and equipment supplier should confirm the proposed rating against project documents and applicable requirements. Switchgear Builder Virginia treats fault duty as a project input, not a stock assumption. Any proposed fault rating or tested configuration must be verified for the quoted build.

Environment and Space

Site conditions help determine enclosure and arrangement requirements. State whether equipment will be indoors or outdoors, and identify exposure to moisture, dust, corrosive agents, temperature extremes, elevation, washdown, or other conditions specified for the location. Describe available room dimensions, access routes, working clearances from the project drawings, cable entry direction, and whether future sections or maintenance access matter. Enclosure type and protective features are options to evaluate against actual exposure and applicable project requirements; avoid assuming that one enclosure designation covers every environmental concern. Greater environmental protection or a compact footprint may influence ventilation, heat management, access, and dimensions, so weigh those choices before the layout is fixed. Provide site plans and installation constraints early. Final enclosure construction, environmental suitability, clearances, and any required evaluation or approval are subject to design review and verification.

Prepare a Quote

A useful specification package brings electrical and physical requirements together: one-line diagram, system voltage and frequency, load and feeder schedules, available fault-current data, grounding details, protection requirements, enclosure and site conditions, cable entry preferences, and the project’s applicable standards. Mark items that are mandatory separately from preferences, and flag open questions rather than filling gaps with assumed ratings. For applicable low-voltage switchboard projects, identify whether UL 891 assembly requirements apply and request confirmation of the proposed assembly’s status; UL 891 is a switchboard standard, not a general rating for every type of switchgear. ([ul.com](https://www.ul.com/services/ul-891-general-coverage-program)) Switchgear Builder Virginia offers custom new builds, short lead times subject to quote, and nationwide shipping. The quote and review process must confirm the design, ratings, schedule, and shipping details; no specification page substitutes for project-specific verification.

Related project guides

START A CONVERSATION

Let’s build the right solution.

Tell us what you’re building, replacing or upgrading. Share the information you have now; project details and availability can be confirmed together.

PREFER TO TALK?

(951) 403-5738

Virginia projects. Nationwide delivery.

This attempts to open a draft in your configured email app; review and send it there. Browser support varies. For immediate assistance, call (951) 403-5738.

Request a quote